Control Systems for Activated Sludge Processes
Abstract New supervisory control strategy designed for wastewater treatment plant (WWTP) with nitrogen removal.
Descrizione The control strategy combines three complementary control loops to optimise the nitrogen removal inpre-denitrifying activated sludge plants. The first controller is designed to maintain the average concentration of the ammonia in the effluent via the automatic selection of the most appropriate DO set point in the aerobic reactors. The second control loop optimises the use of the denitrification potential and finally, the third control loop maintains the selected amount of biomass in the biological reactors by automatic manipulation of the wastage rate. Mobile-averaged windows have been implemented to incorporate commonly used averaged values in the control objectives.
Description including main features/advantages
The main objective of the supervisory control strategy designed for Activated Sludge treatment plants with nutrient removal is the optimisation of the existing plant capacity, improving process stability and effluent quality with minimum cost. Therefore, the automatic supervision was conceived as a way to select, at any moment, the most appropriate set-point for the lower-level controllers, leaving the human decision for the top of the hierarchical plant control structure. It is well known that in a conventional or ‘rigid’ operational strategy of a predenitrificatrion activated sludge plant, the process operator has to select (based on their knowledge and experience) several parameters such as the DO concentration in the aerated volumes, the recirculation flow of nitrates to the anoxic zone and the wasting of the excess of sludge. The concentration of DO in the aerated zones should be maintained at a sufficiently high level to support the growth of the adequate organisms, to guarantee the required nitrification rate and to maintain the required level of mixing, but sufficiently low to save energy, avoid the excess mixing and to reduce, as much as possible, the oxygenation in the anoxic volumes induced by the nitrate recirculation. Nitrification is improved by high DO values; however, lowering the DO set-point not only favours the denitrification in the anoxic zone but also some simultaneous nitrification-denitrification in the aerated zone. It is important to point out that for a conventional WWTP, this DO set-point is not able to eliminate completely the fluctuations in the effluent ammonia. Therefore, it is suggested that a variable DO set-point should be selected to only reach the required (not the minimum) averaged value of the ammonia concentration at the end of the aerated volume.
The synergetic combination of three supervisory control loops facilitates
a stable operation of the biological process, improves the effluent quality and lowers
simultaneously the air flow needed.
Innovative aspects
The control system here presented is based on measurements of real sensors and the
full-scale implementation of the control algorithms is based on experimental data
combined with simulation programs and requires many additional improvement to the
computing code so as to guarantee a safe operation of the process (upper and lower
limits for all the manipulated variables, digital filtering and sampling of the signals,
detection and elimination of outliers, automatic procedures for the initialisation and
commutation of the control loops, etc.).
Current and potential industrial users/domains of application
WWTP operators and technology suppliers.
Current state of development
Tested at lab, pilot and full scale urban WWTP (Galindo, Bilbao, Spain)
Contact details
Organisation
CEIT
Website
www.ceit.es
Contact person
Eduardo Ayesa
Address
P Manuel Lardizabal 15
20018 San Sebastian
Spain
Phone
0034943212800
Fax
0034943213076
Email
eayesa@ceit.es
TRL - technology readiness level 5 Prototipo in grande scala o scala reale.
Link1 http://www.aquafit4use.eu/downloads
Laboratorio TIGRI
Partner ENEA
Topic di ricerca 2.5.2 Trattamento reflui industriali
Risultato LISEA Falso
Risultato Tecnopolo Falso
Topic di ricerca collegati
Code Topic Descrizione ID
2.5.2 Trattamento reflui industriali 41





 

 


 

 

POR FESR

logo rete alta tecnologia emilia romagna


Il Laboratorio ha realizzato progetti finanziati dai Fondi europei della Regione Emilia-Romagna e dal Fondo per lo sviluppo e la coesione
Sitemap
Termini di uso
Politica sulla Privacy
Accessibilita'

Condividi questa pagina con

LinkedIN share Facebook share condividi
Dichiarazione di accessibilità 6d66ae69-c6fd-4cb9-b536-be3fdfb0144c